Our Capability

MEP Services

Design, supply, installation and maintenance across four divisions. Each scope below can be delivered on its own or as part of a single coordinated MEP package — which is how we prefer to work, because it puts one team in charge of every interface.

Division 01

Fire Fighting Systems

The division our name is built on. We design, supply, install, test and maintain complete fire-protection systems — from the pump room to the last sprinkler head — for industrial, commercial and residential buildings.

Quote this scope
01

Fire Pumps

Electric, diesel and jockey pump sets with matched controllers, sized to the system demand and installed as a complete pump room.

02

Automatic Sprinkler Systems

Wet, dry and pre-action sprinkler networks — hydraulic calculation, pipework, heads and valve sets through to flow testing.

03

Foam & CO₂ Suppression

Foam systems for flammable-liquid risk and CO₂ flooding for enclosed high-value plant.

04

FM200 & Novec Systems

Clean-agent gaseous suppression for server rooms, control rooms and electrical substations — protection without water damage.

05

Aerosol Systems

Compact condensed-aerosol units for confined enclosures where cylinder space is unavailable.

06

Fire Hose Cabinets

Landing valves, hose reels and cabinets on standpipe risers, positioned to coverage requirements.

07

Fire Extinguishers

Portable extinguishers selected by risk class, sited, signed and kept in service under maintenance contract.

08

Detection Equipment

Detector selection and layout coordinated with the fire-alarm scope in our electrical division.

09

Kitchen Guard Systems

Wet-chemical suppression over cooking lines and extract hoods for commercial kitchens.

10

Testing & Maintenance

Scheduled inspection, functional testing and servicing to keep systems demonstrably ready.

Division 02

HVAC

Heating, ventilation and air conditioning — from simple extract systems to full chilled-water plant. We handle load calculation, equipment selection, ductwork and pipework installation, balancing and commissioning.

Quote this scope
01

Exhaust Ventilation

Extract systems for kitchens, car parks, plant rooms and process areas, sized to required air-change rates.

02

Supply Ventilation

Filtered fresh-air supply with the fan, duct and diffuser selection to deliver it where it is needed.

03

Balanced Ventilation with Energy Recovery

Supply and extract in balance through a heat-recovery unit — tempered fresh air at a fraction of the cooling load.

04

DX Systems

Direct-expansion cooling for standalone spaces where a central plant is not justified.

05

Concealed Ducted Split Units

Ceiling-void units with short duct runs — even distribution with no visible indoor equipment.

06

Chilled Water Systems

Chillers, pump sets, AHUs and FCUs with the primary and secondary pipework, insulation and controls.

07

VRF / VRV Systems

Variable refrigerant flow for multi-zone buildings needing independent control room by room.

08

Testing & Balancing

Air and water balancing with recorded readings, handed over as commissioning documentation.

Division 03

Plumbing

Everything that carries water into, around and out of a building — supply, drainage, irrigation and treatment. Installed to be maintainable, not just to pass a first pressure test.

Quote this scope
01

Water Supply Systems

Cold and hot water distribution, storage, boosting and pressure control from the incoming main onward.

02

Drainage

Soil, waste and rainwater systems with the falls, venting and access points to keep them serviceable.

03

Irrigation Systems

Landscape irrigation with zoning, controllers and the pipework to distribute it evenly.

04

Resource Management Utilities

Metering and distribution arrangements that let an operator see and control what a building consumes.

05

Water Treatment & Cleansing

Filtration, softening and treatment plant matched to the incoming water quality and the building's use.

06

Testing & Handover

Pressure testing, chlorination and flushing, recorded and certified before handover.

Division 04

Electrical

Power distribution, lighting, life-safety and low-current (LC) systems. Our electrical division also carries the fire-alarm scope, which is why detection and suppression stay coordinated on our projects.

Quote this scope
01

Power Distribution

Main and sub-main distribution, panels, containment and final circuits throughout the building.

02

LV / MV Systems

Low- and medium-voltage distribution including switchgear, transformers and cabling.

03

Lighting

Internal and external lighting design and installation, with control and switching arrangements.

04

Emergency Power

Emergency and escape lighting, standby supplies and the changeover arrangements behind them.

05

Conventional Fire Alarm

Zoned detection and alarm for smaller buildings where zone-level identification is sufficient.

06

Addressable Fire Alarm

Device-level addressable systems for large or complex sites — the scope delivered at TCI-Sanmar.

07

CCTV

Camera coverage, recording and monitoring, installed alongside the electrical containment.

08

Low Current (LC) Systems

Data networks, access control, public address and intercom — installed on the same containment as the power scope.

09

Testing & Certification

Insulation, earth and functional testing with the certification a handover requires.

In practice

See how the addressable fire-alarm scope was delivered in a live chemical plant — TCI-Sanmar reference project.